The furnace worked before the driveway was plowed. Now the thermostat is calling for heat, the furnace makes a brief whirring sound, and the vents never deliver warm air. If this happens at your Donner Lake home this winter, one useful detail is where the snow ended up. A sidewall vent can be clear during a storm and buried afterward by a plow berm or snow sliding off the roof.

If a carbon monoxide alarm sounds, get everyone outside, call 911 from fresh air, and stay out until responders say it is safe. Do not spend time looking for a blocked pipe first. Truckee Fire Protection District advises checking that furnace and other appliance vents stay clear during and after storms.

What a snowbank can interrupt

A direct vent gas furnace needs a clear path to draw in combustion air and another to carry exhaust outside. Those paths may end at two separate openings or share one termination fitting. On many furnaces, a small fan starts before ignition. The controls check that it has established the draft the furnace needs. A blocked opening can interrupt that sequence before the burners light, or cause an operating furnace to shut down.

The brief whir tells us something started. It does not tell us which part failed. Nor does a quiet carbon monoxide alarm tell you that a buried exhaust is safe. If an opening looks blocked or damaged, leave the furnace off and arrange service. Do not repeatedly reset it to get another few minutes of heat.

What you can tell from the ground

From a safe spot, look for a drift against the wall where the vent normally exits. Is the opening buried? Does the pipe look loose or tilted compared with a photo taken before the storm? A picture of the whole area is more helpful to us than a close-up of one pipe: it shows the height of the bank and where the snow came from. Skip the photo if you would have to stand under a loaded roof, climb a ladder, or cross an icy slope.

Do not dig blindly for a buried fitting, chip out ice, or push anything inside a pipe. A vent joint can be damaged even if the part you can see looks intact. If you do not know which opening belongs to the furnace, say so. A nearby dryer outlet is easy to mistake for it.

If the vent looks clear but the heat stays off

We check the full intake and exhaust route against the furnace manufacturer’s instructions. On a condensing furnace we also inspect the path that drains water from the unit. A drain restriction, a problem with the draft fan, or a damaged sensing tube can interrupt startup even when both outdoor openings are clear. We check the draft against the model’s specification before recommending a pressure switch. A switch reporting poor draft may be doing its job.

What happens next depends on the finding. A displaced vent needs a sound, correctly supported connection. A drainage fault needs its own repair. If a bank repeatedly covers an otherwise intact termination, ask us to evaluate its location and the manufacturer’s snow clearance requirements. Extending a pipe yourself can change how the furnace vents. Before returning the system to service, we check the venting, startup, and safe operation through a heating cycle.

Before the next storm, show anyone clearing snow where the openings are and agree on a different place to pile it. If the furnace has already lost heat, contact Fusion Heating and Cooling Inc. for furnace repair. Tell us whether the failure followed snowfall or snow removal, and whether the heat ever came back without a reset.